When I installed a toilet and sink, I installed an air inlet valve under the sink, to provide venting for the waste line.
Each Studor product carries a 10 year warranty if used in accordance with the manufacturer's guidelines. I have a septic system made from two 55-gal drums. then the Air Admittance Valve should be checked and replaced as needed. Once installed, no maintenance is required. Well just like any mechanical device they are subject to problems and failures. Every Studor valve is tested twice before leaving the factory. They perform the same function as a check valve does for water as in the case of sump pump discharge lines.
They perform the same function as a check valve does for water as in the case of sump pump discharge lines. Problems can arise where air admittance valves are fitted to vent pipes which are not separately vented and which include water traps - this can lead to back pressure in the pipework when an appliance is discharged which will effect the appliance discharge - this will be especially noticeable when a toilet is flushed. Using AAVs significantly reduces the amount of materials needed in a plumbing system, increasing plumbing labour efficiency, allowing greater flexibility in the layout of plumbing architecture, and reducing long-term roof maintenance problems associated with conventional vent stack roofing penetrations. Air Admittance Valves Air admittance valves (AAVs) are pressure-activated, one-way mechanical vents, used in a plumbing system to eliminate the need for traditional venting and roof penetrations. Air admittance valves (AAVs) are pressure-activated, one-way mechanical vents, used in a plumbing system to eliminate the need for traditional venting and roof penetrations. Thanks to Studor technology, our range of AAVs react (open) at a very small pressure differential, becoming the preferred technical solution for modern drainage systems.
Air admittance valve problems install#
This is described by a concept called “rapidity of reaction or instantaneous reaction”. If you need to install an air admittance valve, or AAV, to add pipe ventilation, it helps to have plumbing knowledge and the ability to shut off the main water valve to the area if necessary in an. The Studor vent piping system is commonly known as an active system, rather than a conventional ‘passive’ vent pipe system, because the AAV opens when there is a need. According to the Scottish Building Regulations Technical Handbook Section 3.7.8: A Wastewater drainage system serving a building should minimise the possibility of foul air entering the building. If the system goes above these pressures, this can lead to the depletion of the trap seals. This keeps the pressures in the system for discharges between 0 and -250 Pa. Why Studor AAVs are the Preferred Technical Solution Shown with the black cap (Air Admittance Valve) fitted by us. How Air Admittance Valves work The A.A.V.’s should open before -75 Pa, allowing air into the system and relieving the negative transient pressure.